Back to results
Water SA Manuscript

Use of dewatered sludge as microbial inoculum of a subsurface wastewater infiltration system: effect on start-up and pollutant removal

Published: 2017
Report No: 3 367,00
Authors: Pan J, Jiang Y, Zhang Y, Sun Y

Abstract

Brown earth–based subsurface wastewater infiltration systems (SWISs) inoculated with/without dewatered sludge were constructed and operated under the same conditions to boost the application of SWIS in brown soil areas. Start-up period of SWIS with dewatered sludge was 28 days, 12 days shorter than that of SWIS without dewatered sludge. COD, NH 3-N and TN removal efficiencies of dewatered sludge as microbial inoculum for SWIS were higher than that of SWIS without dewatered sludge under hydraulic loading rates (HLR) of 0.04, 0.07, 0.1 and 0.13 m 3·m−2·d−1. Effluent concentrations of COD, NH 3-N and TN in the SWIS inoculated with dewatered sludge were 44.51±4.13, 7.35 ± 0.24 and 14.03 ± 0.31 mg·L −1 under HLR of 0.13 m3·m−2·d−1, which were simultaneously lower than Chinese criteria for water discharge from municipal wastewater treatment plants. The number of bacteria, nitrifying bacteria and denitrifying bacteria in dewatered sludge as microbial inoculum for SWIS were higher than that in SWIS without dewatered sludge under the same HLR.

Authors

PJ
Pan J
JY
Jiang Y
ZY
Zhang Y
SY
Sun Y