Back to results
Water SA Manuscript

Nitrate-nitrogen removal with small-scale reverse osmosis, electrodialysis and ion-exchange units in rural areas

Published: 2009
Report No: 2 360,00
Authors: Schoeman JJ

Abstract

The nitrate-nitrogen concentration in water supplied to clinics in Limpopo Province is too high to be fit for human consumption (35 to 75 mg/ℓ NO3-N). Therefore, small-scale technologies (reverse osmosis, ion-exchange and electrodialysis) were evaluated for nitrate-nitrogen removal to make the water potable (< 10 mg/ℓ NO 3-N). It was found that the reverse osmosis process should function well for nitrate-nitrogen removal. Nitrate-nitrogen could be reduced from a concentration of 35 to 43 mg/ℓ in 1 case to a concentration of between 1.4 and 5.5 mg/ℓ in the treated water. In another case it could be reduced from 54 to 72 mg/ℓ to 12 to 17 mg/ℓ in the treated water. The water was also effectively desalinated. The ionexchange process could also reduce the nitrate-nitrogen concentration to less than 10 mg/ℓ in the treated water. However, the water could not be efficiently desalinated and the process should function better when the level of total dissolved solids in the feed is not very high. The electrodialysis process should also function well for nitrate-nitrogen and salinity removal.

Authors

SJ
Schoeman JJ

Access Report

Free download · PDF format

Related Research