Optimal water meter selection system
Abstract
The comparison of the particular accuracy envelope of a water meter with a consumer’s diurnal demand pattern by means of a common reference facilitates the optimal selection of water meters. The accuracy curve and envelope of a new water meter is governed by the type of water meter and relevant standards. Water demand patterns vary with time, period, seasons, consumers and combinations of these factors. The classical accuracy envelope and demand pattern are not directly comparable, and require a common comparison reference. The relative frequency of the volume of water passing through a meter at various flow rates and the weighted accuracies of these measured volumes play a pivotal role in establishing a common comparison reference. The time unit selected to calculate the volume of water passing through the meter is guided by the type of water reticulation infrastructure within which the meter is installed. However, experience and literature show that a flow interval of less than 1 min would result in the application of unrealistic high flow rates.