Back to results
Water SA Manuscript

Analysis of key variables controlling phosphorus removal in high rate oxidation ponds provided with clarifiers

Published: 2002
Report No: 1 421,00
Authors: García J, Hernández-Mariné M, Mujeriego R

Abstract

This study evaluates the influence of hydraulic retention time (HRT), solar radiation, and water temperature on phosphorus removal from two experimental high rate oxidation ponds (HROP) with clarifiers. Both HROPs were operated for a period of one year with different HRTs (3 to 10 d), but under the same environmental conditions. Phosphorus species, phytoplankton biomass, solar cumulative radiation, water temperature and pH were measured once a week. Average total phosphorus removal (TP) was higher in the HROP operated with a higher HRT (43%) than in that using a lower HRT (32%). TP removal was due to dissolved reactive phosphorus (DRP) removal in the mixed liquor of the HROPs and transformation of DRP into particulate phosphorus (PP), with subsequent sedimentation of PP in the clarifiers. The influence of HRT on TP removal was due mainly to its control over DRP removal, which was observed to be more important in autumn and winter.

Authors

GJ
García J
HM
Hernández-Mariné M
MR
Mujeriego R

Categories

Access Report