Back to results
Water SA Manuscript

Flow-gauging structures in South African rivers Part 2: Calibration

Published: 2009
Report No: 2 212,20
Authors: Rooseboom A, Wessels P

Abstract

1 January 2009 ISSN 1816-7950 = Water SA (on-line) 14 Water Project. 0. In this assessment it was recognised that the DWAF equations were designed to cover a wide range of upstream pool depths and describe these flow conditions better than alternative formulae. Rating of sharp-crested (thin-plate) weirs for non-modular flow conditions Thin-plate weirs are usually designed to operate only under modular flow conditions. In South Africa, sharp-crested weirs are widely used to gauge flow in natural streams. It happens quite often that downstream water levels are higher than the crest elevations of these weirs.

Authors

RA
Rooseboom A
WP
Wessels P

Access Report

Free download · PDF format

Related Research